<LOGO>
FM Transmitter Measurement Report
Created: 2026-01-20 01-39-30
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 38 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.1 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
20 kHz 25 kHz 1361 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,6 dBr 5,44 dBr 6,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 25 kHz MIN: 20 kHz % above 76 kHz: 0,0000 Acquired: 2026/01/20 1.38.25 Total samples: 1361 Equivalent time: 0:01:08 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 20 40 60
FM Scope MAX: 6,2 dBr MIN: 4,6 dBr AVE: 5,44 dBr % above 12,2 dBr: 0,0 Last value: 5,8 dBr (2026/01/20 1.38.25) 01.24 01.26 01.28 01.30 01.32 01.34 01.36 01.38 0 2 4 6 Pm [dBr]